Air Flow EC Centrifugal Fans For Air Exchanger With External Rotor Motor

Ask Latest Price
Video Channel
Brand Name :OFAN
Model Number :LD280C-230D3-01
Certification :CE ROHS
Place of Origin :China
MOQ :1pcs
Price :negotiation
Supply Ability :10000PCS
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :5-8 work days
Packaging Details :45*45*24
Power :170W
Rated Speed :2150RPM
Air Flow :1900m³/h
Nominal voltage :230V
Type :LD280C-230D3-01
Current draw :1.2A
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Air Flow EC Centrifugal Fans For Air Exchanger With External Rotor Motor

​Type

Nomual voltage

(VAC)

Frequency

(HZ)

Speed

(rpm)

Power imput

(w)

Curreng draw

(A)

Sound pressurelevel

(dB)

Perm.amb.temp
LD280C-230D3-01 230 50/60 2150 170 1.2 60

-20~+60

Power factor correction(PFC): Passive and active(IEC61000-3-2)

Soft start, adjustable acceleration, CVT

Design operating temperature range: -30~60 degrees of minimum selection(The device in accordance with -40~85 degrees)

Protection: over voltage, over temperature, over current, phase loss detection, communication failures.

The basic interface: 0-10V/PWM, RS485/Modbus, 4-20Ma

The basic parameters of field programmable: Maximum speed, minimum speed, maximum power,

Let’s assume a laminar flow workstation requiring 13200m³/h at 450Pa. This requires 4 off Ø315 backward curved fans.

Now let us assume that this workstation operates for 50 weeks of the year and for 8 hours per day at full speed. During non working hours to

maintain the work area, the fans are run at roughly half the airflow.

AC fan 2800hrs @ 4 x 1.41kW = 5.64kW 15,792 kWh
5600hrs @ 4 x 0.62kW = 2.48kW 13,888 kWh
Total A 29,680 kWh
EC fan 2800 hrs @ 4 x 1.04kW = 4.16kW 11,648 kWh
5600 hrs @ 4 x 0.27kW = 1.08kW 6,048 kWh
Total B 17,696 kWh
A minus B 11,984kWh saved with the EC fan

aster/Slave : This system is used when several fans are used together within a single application. The main fan (Master) is individually pressure

controlled. The other fans (slaves) are then speed controlled by the Master fan : Slave Fans are always at the speed of the master fan (Rosenberg Versions only).